| External dimensions | 6,0 × 7,0 m | 7,0 × 12,0 m | 9,0 × 14,0 m |
|---|
| Overall height | 2,60 m | 2,60 m | 2,60 m |
|---|
| Clear internal height | 2,35 m | 2,35 m | 2,35 m |
|---|
| Structural system | Welded steel chassis and galvanised lightweight steel superstructure | Welded steel chassis and galvanised lightweight steel superstructure; reinforced inter-module connection | Welded steel chassis and galvanised lightweight steel superstructure; reinforced inter-module connection |
|---|
| Internal walls | Easy-clean panel partition; optional acoustic layer between rooms | Easy-clean panel partition; optional acoustic layer between rooms | Easy-clean panel partition; optional acoustic layer between rooms |
|---|
| External walls | 50 mm insulated sandwich panel; RAL colour options | 50 mm insulated sandwich panel; RAL colour options | 50 mm insulated sandwich panel; RAL colour options |
|---|
| Roof | Galvanised structure, trapezoidal sheet, vapour barrier and 80 mm insulation; rainwater drainage | Galvanised structure, trapezoidal sheet, vapour barrier and 80 mm insulation; rainwater drainage | Galvanised structure, trapezoidal sheet, vapour barrier and 80 mm insulation; rainwater drainage |
|---|
| External door | 900 × 2100 mm insulated steel external door | 900 × 2100 mm insulated steel external door | 900 × 2100 mm insulated steel external door |
|---|
| Internal doors | Laminated internal doors; moisture-resistant doors in wet areas | Laminated internal doors; moisture-resistant doors in wet areas | Laminated internal doors; moisture-resistant doors in wet areas |
|---|
| Windows | PVC/aluminium frames, 4+12+4 double glazing | PVC/aluminium frames, 4+12+4 double glazing | PVC/aluminium frames, 4+12+4 double glazing |
|---|
| Floor | Steel subframe, cement board and commercial-grade PVC finish | Steel subframe, cement board and commercial-grade PVC finish | Steel subframe, cement board and commercial-grade PVC finish |
|---|
| Electrical | Room-based sockets and lighting, residual-current protection and emergency-lighting provision | Room-based sockets and lighting, residual-current protection and emergency-lighting provision | Room-based sockets and lighting, residual-current protection and emergency-lighting provision |
|---|
| Plumbing | Fresh and waste water services to project; tested connections prepared | Fresh and waste water services to project; tested connections prepared | Fresh and waste water services to project; tested connections prepared |
|---|
| Insulation | 50 mm wall and 80 mm roof insulation; can be increased for the climate zone | 50 mm wall and 80 mm roof insulation; can be increased for the climate zone | 50 mm wall and 80 mm roof insulation; can be increased for the climate zone |
|---|