| External dimensions | 3,0 × 5,0 m | 3,0 × 7,0 m | 3,0 × 10,0 m |
|---|
| Overall height | 2,60 m | 2,60 m | 2,60 m |
|---|
| Clear internal height | 2,35 m | 2,35 m | 2,35 m |
|---|
| Structural system | Galvanised and painted steel, demountable bolted chassis and frame | Galvanised and painted steel, demountable bolted chassis and frame | Galvanised and painted steel, demountable bolted chassis and frame |
|---|
| Internal walls | 50 mm insulated partition panel; easy-clean surface | 50 mm insulated partition panel; easy-clean surface | 50 mm insulated partition panel; easy-clean surface |
|---|
| External walls | 50 mm insulated sandwich panel; RAL colour options | 50 mm insulated sandwich panel; RAL colour options | 50 mm insulated sandwich panel; RAL colour options |
|---|
| Roof | Galvanised structure, trapezoidal sheet, vapour barrier and 80 mm insulation; rainwater drainage | Galvanised structure, trapezoidal sheet, vapour barrier and 80 mm insulation; rainwater drainage | Galvanised structure, trapezoidal sheet, vapour barrier and 80 mm insulation; rainwater drainage |
|---|
| External door | 900 × 2100 mm insulated steel external door | 900 × 2100 mm insulated steel external door | 900 × 2100 mm insulated steel external door |
|---|
| Internal doors | Laminated internal doors; moisture-resistant doors in wet areas | Laminated internal doors; moisture-resistant doors in wet areas | Laminated internal doors; moisture-resistant doors in wet areas |
|---|
| Windows | PVC/aluminium frames, 4+12+4 double glazing | PVC/aluminium frames, 4+12+4 double glazing | PVC/aluminium frames, 4+12+4 double glazing |
|---|
| Floor | Steel subframe, cement board and commercial-grade PVC finish | Steel subframe, cement board and commercial-grade PVC finish | Steel subframe, cement board and commercial-grade PVC finish |
|---|
| Electrical | RCD-protected distribution board, LED lighting, socket circuit and earthing | RCD-protected distribution board, LED lighting, socket circuit and earthing | RCD-protected distribution board, LED lighting, socket circuit and earthing |
|---|
| Plumbing | Fresh and waste water services to project; tested connections prepared | Fresh and waste water services to project; tested connections prepared | Fresh and waste water services to project; tested connections prepared |
|---|
| Insulation | 50 mm wall and 80 mm roof insulation; can be increased for the climate zone | 50 mm wall and 80 mm roof insulation; can be increased for the climate zone | 50 mm wall and 80 mm roof insulation; can be increased for the climate zone |
|---|