| External dimensions | 2,0 × 2,0 m | 2,0 × 3,0 m | 3,0 × 3,0 m |
|---|
| Overall height | 2,50 m | 2,50 m | 2,50 m |
|---|
| Clear internal height | 2,25 m | 2,25 m | 2,25 m |
|---|
| Structural system | Galvanised lightweight steel bolted frame | Galvanised lightweight steel bolted frame | Galvanised lightweight steel bolted frame |
|---|
| Internal walls | Water-resistant hygienic panel with sealed joint profiles | Water-resistant hygienic panel with sealed joint profiles | Water-resistant hygienic panel with sealed joint profiles |
|---|
| External walls | 50 mm insulated sandwich panel; RAL colour options | 50 mm insulated sandwich panel; RAL colour options | 50 mm insulated sandwich panel; RAL colour options |
|---|
| Roof | Galvanised structure, trapezoidal sheet, vapour barrier and 80 mm insulation; rainwater drainage | Galvanised structure, trapezoidal sheet, vapour barrier and 80 mm insulation; rainwater drainage | Galvanised structure, trapezoidal sheet, vapour barrier and 80 mm insulation; rainwater drainage |
|---|
| External door | 900 × 2100 mm insulated steel external door | 900 × 2100 mm insulated steel external door | 900 × 2100 mm insulated steel external door |
|---|
| Internal doors | Laminated internal doors; moisture-resistant doors in wet areas | Laminated internal doors; moisture-resistant doors in wet areas | Laminated internal doors; moisture-resistant doors in wet areas |
|---|
| Windows | High-level obscured-glass PVC/aluminium windows | High-level obscured-glass PVC/aluminium windows | High-level obscured-glass PVC/aluminium windows |
|---|
| Floor | Slip-resistant wet-area finish with controlled falls to floor drains | Slip-resistant wet-area finish with controlled falls to floor drains | Slip-resistant wet-area finish with controlled falls to floor drains |
|---|
| Electrical | RCD-protected distribution board, LED lighting, socket circuit and earthing | RCD-protected distribution board, LED lighting, socket circuit and earthing | RCD-protected distribution board, LED lighting, socket circuit and earthing |
|---|
| Plumbing | PPRC cold water, PVC waste, floor drain, ventilation and hot-water provision | PPRC cold water, PVC waste, floor drain, ventilation and hot-water provision | PPRC cold water, PVC waste, floor drain, ventilation and hot-water provision |
|---|
| Insulation | 50 mm wall and 80 mm roof insulation; can be increased for the climate zone | 50 mm wall and 80 mm roof insulation; can be increased for the climate zone | 50 mm wall and 80 mm roof insulation; can be increased for the climate zone |
|---|